Split Air condition Installation Guide

Split Air condition Installation Guide

1 - Never input or outputDo not block ventilation air conditioning.
This could result in the return air, exhaust air directly to the device or Nrysdn enough The device. Also back to direct air from the output, reduce the efficiency The device comes in both indoor and outdoor unit, good heat exchange between the air and refrigerant Abnormal pressure in the system is not doing a long-term and severe damage to Compressors are. Indoor and outdoor units split systems must be installed in the space Adequate air flow for heat exchange exists, otherwise it returns the Greatly reduced.

2 - Never HVAC systems in close protection Qrarndhyd. This may cause exhaust air directly inserted Problem is lack of proper function. Furthermore, the device is also difficult to access services Was. Resulting in loss of efficiency caused by the device and ultimately damage the compressor Will. ( Spaces required for the functioning of the system catalog tables and Engineering Firms Extract the manufacturer.)

install-a-split-system-air-conditioner
3 - any other input device output device should be facing outward.
This is a drop in output efficiency. If you are installing multiple devices together Install them side by side or back to back. Check out the hot air from an efficiency Rvyrv device greatly reduced.

4 - circulates air in the correct external device accurately Please.
Wind speed should be more than 7 meters per second. If Karnkrdn external fan may Damage is to be logged. Note that the unit must be external to Be installed to face the wind, it is not reported. Otherwise reduce efficiency Will.

5 - to install the external device, take care.

  • This The probability of snow accumulating on the device in places where there are no setup.
  • If this unit is installed in a garage, the car in front of you The park does not block the airway.
  • Increase device efficiency and lower power consumption is existence. Also used in If that does not disturb the air flow through the canopy is recommended.

6 - When the device is installed inside a wall You take care to make sure the drain pipe is installed perfectly level to waters The system does not leak.
Note: Never use two common drain pipe.

7 - Place the installation and repair service in the right place, consider the case Do not trouble trouble and in need of repairs. Recommended on the device Installed on the roof or terrace to easily access it when needed.

8 - Place of installation due to external noise and vibration and heat output varying predictions Please. Noise and heat output of the external device may cause inconvenience consumption And others.

9 - Thermal generators installed around the outer And chimneys is wrong, because it decreases the efficiency of the device will fail.

10 - internal devices on the correct surface and flush mounting please. Lack of proper installation Improper distribution of refrigerant in the coil system may not drain properly and water distillation And water to Dygrchkh parts.

11 - a good distance from the surface to the inside ceiling is installed. Otherwise, the distribution is not properly cooling or heating and air-launched Will be made as appropriate.

12 - The temperature can be adjusted as appropriate. Otherwise cause premature wear The device will be.

13 - split expose internal devices do not install hot and humid outside. This will result in the loss of cooling and condensation of moisture in the accumulation of water around the Be. Also, the air entering and leaving the room air out into the room in a long Avoid long, because it greatly reduces the system efficiency.

14 - internal devices, especially in the heating mode Must be installed to the proper location for the distribution of air temperature in all environments there Vjryan Be.

15 - internal devices in places where the air contains smoke, fine particles and Grdghbar (Such as industrial kitchens and workshops) Do not install. Because of congestion Filter and the evaporator coil and eventually results in loss of performance of the system is. The devices Industrial and workshop it is not appropriate for use in industrial conditions should Select the appropriate device and installation conditions.

16 - Do not install equipment exposed to severe vibration and noise, vibration and noise Lathe machines and devices such as microprocessors can be fierce on sensitive parts It can affect and damage.

install-a-split-system-air-conditioner
17 - Be careful when installing, dust and particulates into the refrigerant pipes Not. These particles may block the capillary tubes or compressor damage Vmvjb shorten the life of the compressor. When the head tube is open only by a Close the lid and dust particles from entering the inside of the pipe to prevent.Inside the Tube Copper from the plumbing before you buy nitrogen gas clean up Of dust or particulates may be discharged.

18 - Be careful that water does not enter the refrigerant pipes. Water entering the system And refrigerant pipes, capillary tubes or compressor shut down and damages. When The head tube is open, be careful not to water them, and on rainy days, Under the rain, do not tap because rain water and moisture that may enter tubes Be.

19 - Immediately after opening the cap pipes connect to the pipes. Because air and moisture into the piping system is very dangerous and can cause pressure Abnormal and harmful acids produced in the system and continue to cause damage to the compressor. Will.

20 - When charging refrigerant into the system, never make the capsule upside. This It may cause liquid entering the liquid entering the compressor and compressor damage Will, because liquids are not compressible. ( The gas R407c and R410a must Two refrigerant liquid must be injected into the system.)

21 - Never Do not clean with oxygen tubes in the refrigerant cycle. It Explosion in the oxygen cycle and the compressor housing combined with oil Compressor Compressor will cause fire or Nfjar.

22 - when the cap is open and the plumbing is not currently carried Is probably beginning and end of the tube with a cap block. Otherwise Be moisture, dust and particulates into the future and cause damage to the system.

23 - Make sure the drain pipe clamps with adhesive or sealing length. Meanwhile, the head of internal devices that connect these unused sure the lid is closed Length.

24 - After installation and plumbing systems, pipes and fittings, especially the areas shown (By screw connections and service valves) If the leak test. Soapy water can be Dilute it did. Note that the leakage issue, make sure the pipes Clean soap.

25 - Do not tap more than the standard length. Piping The standard length of the efficiency loss, poor oil circulation system Compressor will eventually fail.

26 - never both indoor and outdoor unit at a level different from standard installation Do not. This accumulation of oil inside the compressor unit and return it Yvnya outside the compressor and damage the compressor is the problem.

27 - Be careful with your knees bent pipe. Select a route that minimizes Bending is required. It causes severe performance degradation or leakage devices Is gas. Also make sure the pipe and tube bender right angle bend. Vigilant If the pipe is not crushed or flattened.

28 - Note the size refrigerant pipes. If the wrong pipe size For proper operation and long life can be expected.